ABOUT US

PRODUCTS

INQUIRY

CONTACT

E-MAIL

 

POLYLINK POLYMERS (INDIA) LTD.                                                              Products

Compounds for Power Cables

Thermoplastic Semiconductive Compound
for Conductor / Insulation Shielding of Power Cables Grade - P-10040-CB

DESCRIPTION :

P-10040-CB is a defromation resistant semiconductive compound designed for use as shielding material both for conductior and insulation of power cable core. The compound is characterixed by its good stress crack resistance , balanced, volume, resistance,balanced volume resistivity and excellent proessability.

APPLICATION :

P-10040-CB is suitable as shielding material for cables up to 33 Kv. It is rated for 90deg.C continuous service and 130 deg.C overload temperature.

TECHNICAL DATASHEET : 

Property

Test Method

Unit

Typical value

Density

ASTM-D-1505

gm / cm3

1.12

MFI at 190° C / 5 Kg.

ASTM-D-1238

G / 10

0.91

Unaged mechanical properties:

     

Tensile Strength at Break

ASTM-D-638

Kg. / cm2

125

Elongation at Break

ASTM-D-638

%

300

Heat Distortion Temp.

ASTM-D-648

° C

62 

Vicat softening point

ASTM-D-1525

° C

96

ESCR, 50° C / 10% Igeopol soln.

IEC811

hr

>100

Volume Resistivity

ASTM-D-257

ohm.cm

500



RECOMMENDED EXTRUSION CONDITIONS :


Extruder 

The compound is extrudable in conventional polyethylene wire and cable extrusion line.

Pre – Drying 

P-10040-CB shall be pre dried before use,Usually 3-5 hr drying in dehumidified hopper at 70-80 deg.C is sufficient unless compound is exposed to atmosphere for long period.

Temperature profile for extrusion

Zone 1 Zone 2 Zone 3 Zone 4 Head Die
130° C 140° C 150° C 160° C 170° C 170° C

 
· Actual conditions may vary according to the type of extruder used 

Screw cooling : 70° C

FORM AND PACKING :

Delivery Form : pellets
Packing : 20 Kg PE bags packed in 230 Lt HDPE container

This information is to the best of our knowledge. The values of different parameters and operating conditions listed above are guidance only and should not be used for drawing specifications. The results & operating conditions may vary depending on methods of test and manufacturing / testing equipments.